Product Tag - Lightning Protection System

  • ABB Lightning Protection SystemABB LPS Details
    0 out of 5

    ABB Digital Lightning Protection

    Digital Lightning Protection System

    Type : Early Streamer Emission System, Digital Lightning Protection System or Single Rod System.
    Standard :  NFC 17-102
    Size: Various Size is available. Common Sizes are.
    Advanced Triggering Time : 30-60 micro-second.
    Protection Radius : 107-meter Level IV protection with 5 meter elevation mas.
    LPS Protection Level : Level I, Level II, Level III & Level IV
    Materials: Copper, Copper Aloy, Stainless Steel.

    General Information

    Extended Product Type: OPR 60 ABB
    Product ID: 2CTB899800R7100
    EAN: 3660308513502
    Catalog Description: OPR 60 ABB
    Long Description: B751350

    Benefits 
    • Greater Protection Coverage than the conventional system.
    • Possible to protect several buildings with the same lightning conductor
    • Economic
    • Possible to protect a structure and its surrounding environment at the same time
    • Protection of open zones
    • Can be integrated seamlessly and discreetly into the building structure
  • ABB Lightning Protection SystemABB LPS Details
    0 out of 5

    ABB Lightning Protection

    ESE Lightning Protection System

    Type : Early Streamer Emission System, Digital Lightning Protection System or Single Rod System.
    Standard :  NFC 17-102
    Size: Various Size is available. Common Sizes are.
    Advanced Triggering Time : 30-60 micro-second.
    Protection Radius : 107-meter Level IV protection with 5 meter elevation mas.
    LPS Protection Level : Level I, Level II, Level III & Level IV
    Materials: Copper, Copper Aloy, Stainless Steel.

    General Information

    Extended Product Type: OPR 60 ABB
    Product ID: 2CTB899800R7100
    EAN: 3660308513502
    Catalog Description: OPR 60 ABB
    Long Description: B751350

    Benefits 
    • Greater Protection Coverage than the conventional system.
    • Possible to protect several buildings with the same lightning conductor
    • Economic
    • Possible to protect a structure and its surrounding environment at the same time
    • Protection of open zones
    • Can be integrated seamlessly and discreetly into the building structure
  • ESE Lightning Protection SystemABB OPR 60 Device
    0 out of 5

    ABB Lightning Protection System

    • If the area to be protected is a dangerous area, lightning conductor can be installed outside
    • Possible to protect several buildings with the same lightning conductor
    • Economic
    • Possible to protect a structure and its surrounding environment at the same time
    • Protection of open zones
    • Can be integrated seamlessly and discreetly into the building structure
  • 0 out of 5

    Air Terminal

    Air Terminal

    Air Termination device or Air Terminal is the elementary part of a Lightning Protection System. Innovern Engineering is the manufacturer, Supplier and installer of  Air terminal of different sizes and Classes. We are ensuring that our devices are comply with the necessary standard like NFPA 780, UL96 and IEC-62305 etc. We offer various type such as Copper, Aluminum, Nickel Coated Copper, Copper Clad etc. products to our valuable clients.  


    Class I & Class II Air Terminal
    Height : 12 inch, 18 inch and 24 inch,
    Diameter : 9.5 mm to 15.9 mm
    Materials : Copper, Copper Alloy, Aluminum, Aluminum Alloy, Stainless Steel & Other permitted metal.
    Thread : Imperial & Metric thread
    Quliaty : Best quality.

    ৳ 1,850.00
  • Aluminum Cable
    0 out of 5

    Aluminum Cable

    Innovern Engineering is one of the best Lightning Protection System installer in the country. Also supply best quality LPS Products including Aluminum Stranded Cable.

    Size: 50 mm2 for ClassI / 98 mm2 for ClassII
    LPS Class: Class I / Class II
    No. Of Strand: 7, 19 or 37
    Materials: Aluminum
    Standard: UL96, NFPA 780, IEC-62305

  • Aluminum WireALUMINUM CONDUCTOR WIRE
    0 out of 5

    Aluminum Wire

    Innovern Engineering is one of the best Lightning Protection System installer in the country. Also supply best quality LPS Products including Aluminum Stranded Cable.

    Size: 50 mm2 for ClassI / 98 mm2 for ClassII
    LPS Class: Class I / Class II
    No. Of Strand: 7, 19 or 37
    Materials: Aluminum
    Standard: UL96, NFPA 780, IEC-62305

  • Lightning Protection ServiceMeshed Conductor System
    0 out of 5

    Conventional Lightning Protection System

    • If the area to be protected is a dangerous area, lightning conductor can be installed outside
    • Possible to protect several buildings with the same lightning conductor
    • Economic
    • Possible to protect a structure and its surrounding environment at the same time
    • Protection of open zones
    • Can be integrated seamlessly and discreetly into the building structure
  • ESE Lightning Protection SystemABB Lightning Protection System
    0 out of 5

    Digital Lightning Protection System

    • If the area to be protected is a dangerous area, lightning conductor can be installed outside
    • Possible to protect several buildings with the same lightning conductor
    • Economic
    • Possible to protect a structure and its surrounding environment at the same time
    • Protection of open zones
    • Can be integrated seamlessly and discreetly into the building structure
  • Grounding System DetailsGrid Earthing System
    0 out of 5

    Earthing System Products

    Grounding Equipment

    Grounding Type: Rod Grounding, Plate Grounding, Chemical Grounding & Pipe Grounding.
    Materials: Copper, Galvanized Iron (GI), Grounding Enhancement Materials, Stainless Steel etc.
    Size: Various Size.
    Availability : Ready Stock.
    Standard: BNBC, NFPA, IEC, IEEE etc.

  • ESE Lightning Protection SystemABB Lightning Protection System
    0 out of 5

    ESE Lightning Protection System

    ESE Lightning Protection System

    Type : Early Streamer Emission System, Digital Lightning Protection System or Single Rod System.
    Standard :  NFC 17-102
    Size: Various Size is available. Common Sizes are.
    Advanced Triggering Time : 30-60 micro-second.
    Protection Radius : 107-meter Level IV protection with 5 meter elevation mas.
    LPS Protection Level : Level I, Level II, Level III & Level IV
    Materials: Copper, Copper Aloy, Stainless Steel.

    General Information

    Extended Product Type: OPR 60 ABB
    Product ID: 2CTB899800R7100
    EAN: 3660308513502
    Catalog Description: OPR 60 ABB
    Long Description: B751350

     

  • Grounding System DetailsGrid Earthing System
    0 out of 5

    Grounding Equipment

    Grounding Equipment

    Grounding Type: Rod Grounding, Plate Grounding, Chemical Grounding & Pipe Grounding.
    Materials: Copper, Galvanized Iron (GI), Grounding Enhancement Materials, Stainless Steel etc.
    Size: Various Size.
    Availability : Ready Stock.
    Standard: BNBC, NFPA, IEC, IEEE etc.

  • IEC 62305 Standard LPS
    0 out of 5

    IEC 62305 Based Lightning Protection System

    IEC 62305 Standard Lightning Protection System

    Method:   Meshed Conductor System, Conventional System,
    Standard: IEC 62305
    Materials: Copper, Brass, Aluminum, Cast Aluminum, Stainless Steel as per UL96, IEC, and NFPA.
    Structure for protection: Mesonary RCC Building, Large Industrial Shed, Tower, Multi-storied, Skyscrapers